LP/PROPANE TANK REQUIREMENTS
A dented or rusty LP/Propane tank may be hazardous and should be checked by your LP/Propane supplier. Never use
a cylinder with a damaged valve. All tanks should be equipped with an OPD (overfilling protection device). This is a
DOT requirement for all tanks purchased after October 1, 1998, and will ensure that the tank is not overfilled. The
LP/Propane tank should be a standard 5-gal., 20 lb. gas cylinder tank approximately 12” (3.1 cm) in diameter and 18”
(45.7 cm) high which must be constructed and marked in accordance with the specifications for LP/Propane gas
cylinders of the U.S. Department of Transportation (DOT) and designed for use with a Type 1, QCC-1 system only. The
cylinder must be provided with a shut-off valve terminating in an LP/Propane gas supply cylinder valve outlet specified,
as applicable, for a Type 1, QCC-1 connection. The cylinder used must include a collar to protect the cylinder valve.
The cylinder supply system must be arranged for vapor withdrawal and provided with a listed overfilling prevention
device. If the appliance is stored indoors the cylinder must be disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-vented area out of the reach of children.
BURNER ADJUSTMENTS
To gain access to the burner for adjustments:
1. Remove the grate and grate support.
2. Locate the air shutter “A” and loosen the two screws “B” that holds the
air shutter in place.
3. Light the burner and turn the burner knob to the high position.
4. With a proper, high flame height, adjust the air shutter to obtain a blue
flame with no yellow tipping that sits on the burner at the burner ports.
(a) open the air shutter gap to add more air and to eliminate yellow
tipping.
(b) close the air shutter gap to reduce the air and to prevent a noisy
flame that lifts off the burner.
5. Turn the surface burners off.
6. Tighten the air shutter screws.
7. Replace the grate support and grate.
INITIAL IGNITION OF BURNERS
All appliances are tested before leaving the factory. Field adjustments may be necessary for proper mixture of gas and
air for proper operation. When the unit is connected to gas and electrical service, it should be adjusted by a qualified
technician. If it is not, contact your dealer for the name of their authorized service agency. If none are available,
contact Viking Range Corporation for the nearest authorized service agency in your area.
A
B
AIR SHUTTER
6
Air Shutter
Orifice
FLAME HEIGHT
3
/4” (1.91 cm)
OVERHEAD VIEW