Página 1

VIKING RANGE CORPORATION, P. O. DRAWER 956, GREENWOOD, MS.38930 USA F90600A 11/20/03

Página 2 - TABLE OF CONTENTS

WOOD/COMPOSITE OVERLAY INSTALLATION The bottom of the hood should be no less than 27” (68.6cm) above the grates. It is more desirable for the bottom

Página 3 - MUST BE PROPERLY GROUNDED

COMPONENTS (WITH COLOR CODED WIRIES) CONTROL CIRCUIT BOARD (P.C. BOARD) DUAL FUEL SELF-CLEAN FREE-STANDING RANGES WITH SEALED BURNERS Function: The

Página 4

HIGH LIMIT SWITCH: DUAL FUEL SELF- CLEAN FREE-STANDING RANGES WITH SEALED BURNERS Function: The Switch has a ½ “ bi-metal disc. The two metals hav

Página 5

COMPONENTS (continued) DOOR LOCK MOTOR:DUAL FUEL SELF-CLEAN FREESTANDING RANGES WITH SEALED BURNERS’ Function: When the Door Lock Motor is powered i

Página 6

COMPONENTS (continued) RELAY #2 – #3 - #5 (PM010025): DUAL FUEL SELF-CLEAN FREE- STANDING RANGES WITH SEALED BURNERS. Function: Setting the selecto

Página 7

COMPONENTS (continued) CONVECTION FAN MOTOR:DUAL FUEL SELF-CLEAN FREE STANDING RANGES WITH SEALED BURNERS Function: Provides an even flow of air

Página 8

P.C. CONTROL BOARD WIRING FOR RELAYS T4 – T3 – T2 – T1 – T6 – T5 16

Página 9

VOLTAGE READINGS MEASURED WITH DOOR OPEN T4 107VAC 70VAC T3 4VAC 16VAC T2 4VAC 16VAC T1 5VAC 1VAC MEASURED WITH DOOR LOC

Página 10

8 POSITION SELECTORSWITCH (With shaft position and internal connections) 18 SELF CLEAN Selector Switch c

Página 11 - COMPONENTS

OVEN TEMPERATURE CALIBRATION DUAL FUEL RANGES SELF-CLEAN FREESTANDING RANGES WITH SEALED BURNERS Electric oven calibration using the EATON therm

Página 12

TABLE OF CONTENTS TABLE OF CONTENTS---------------------- 2 Customer information------------------------ 3 Model / Serial Number Logic---------------

Página 13

VOLTAGE and RESISTANCE READINGS BAKE ELEMENT: “A” to “B” 21.1 Ohms “A” to “B” 240VAC during Bake and Convection Bake.

Página 14 - VDSC485 (LH )

VDSC367 DISASSEMBLY . Surface Burner Spark Module ol Lock D. otor ard rd t inator Exhaust M. ices AB. Relays #1 and #2 C. Air Channel to C

Página 15

RANGETOP To gain access to the components beneath the top assembly (1) Remove the Grates , (2) Burner Caps, (3) Remove the Burner

Página 16 - P.C. CONTROL BOARD WIRING

GRIDDLE ASSEMBLY A. Thermal Bulb tube Use care to remove the Thermal Bulb from the bulb tube. After removing the Thermal Bulb the Griddle can

Página 17

With the Control Panel pulled forward you can service the following components. A. Spark Igniter Switches B. Screws that hold the Landing Ledge (H) t

Página 18

To complete the removal of the main top: A. Remove the each side trim (X) B. Remove the brackets that hold the main top in place. A. Re

Página 19 - OVEN TEMPERATURE CALIBRATION

A. To remove the burner base: B. Remove the two screws marked (B above) that hold each burner base to the support. C. The Burner Base (A below

Página 20

Remove the Heat Shield (A) to service the Griddle Gas Burner, Igniter, Thermostat Sensor Bulb. A. Igni

Página 21

A Griddle Gas Valve B Heat Shield C Orifice Hood D Air Shutter Griddle Valve and Igniter electrical circuit 28

Página 22

Igniter System - The igniter is wired in series with the gas valve. The gas valve receives approximately 3.3 volts ± 1v, while the igniter obtains ap

Página 23

GENERAL INFORMATION 1. WARNING: The use of cabinets for storage above the appliance may result in a potential burn hazard. Combustible items may ig

Página 24

Remove screws marked (A) to gain access the door lock motor (B) and associated components, Fan Switch (C) and High Limit Switch (D). E Orifice Hood

Página 25

COMBUSTION OF GAS A. The Meaning of Combustion - When oxygen acts with a substance to produce large amounts of heat rapidly (and usually light), th

Página 26

GAS CONNECTION All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greate

Página 27

Add a street elbow to the input gas line at the rear of the range to keep the flex line from having to bend over the edges of the back panel. The LP o

Página 28

Natural to LP/Propane Conversion (For Sealed Burners) This product is manufactured and adjusted for operation with natural gas as shipped from the fa

Página 29 - Igniter System

ELECTRICAL CONNECTION Use a 3 - wire power supply cord kit rated for 30 amps - 125/250 volts for Models VDSC and VERT or 50 amps - 240 volts for Mode

Página 30

ELECTRICAL CONNECTIONS WITH CONDUIT Use ½" trade size conduit with a conduit clamp, 12 AWG /600 volt copper conductor colored red for line # 1 a

Página 31

SURFACE BURNER SPARK MODULE The surface burner spark module is located on the rear of the unit, see above for location. Check your module for the

Página 33

COMPONENT CONTACTS FOR VDSC367 39

Página 35

WIRING DIAGRAM VDSC367 (36”) 40

Página 36

WIRING DIAGRAM SURFACE BURNERS VGSC367 41

Página 37

WIRING DIAGRAM DUAL FUEL 48” W RANGE 42

Página 38

COMPONENT CONTACTS FOR VDSC487 43

Página 39

VDSC367 /487 BAKE Bake Initial Cycle with Pre-Heat 44

Página 40 - WIRING DIAGRAM

VDSC367 / 487 BAKE OVEN Convection Bake 45

Página 41 - VGSC367

VDSC367 / 487 BAKE OVEN Convection Cook 46

Página 42

VDSC367 / 487 BAKE OVEN Broil 47

Página 43

VDSC367 / 487 BAKE OVEN Maxi Broil 48

Página 44 - VDSC367 /487 BAKE

VDSC367 / 487 BAKE OVEN Convection Broil 49

Página 46 - Convection Cook

VDSC367 / 487 BAKE OVEN SELF-CLEAN • 10 seconds after the signal to Sensor #3, switch LS2-M1 is opened, stopping the door lock motion and switches

Página 47

51 UIT FOR THE LEFT HAND OVEN VDSC487 L.H. OVEN SELF-CLEAN• 10 seconds after the signal to Sensor #3, switch LS2-M1 is opened, stopping the doo

Página 48 - Maxi Broil

TROUBLESHOOTING GUIDE ---Dual Fuel / Self-clean / VDSC PROBLEM PROBABLE CAUSE

Página 49 - Convection Broil

TROUBLESHOOTING GUIDE ----Dual Fuel / Self-clean / VDSC PROBLEM PROBABLE CAUSE

Página 50

TROUBLESHOOTING GUIDE ---Dual Fuel / Self-clean / VDSC PROBLEM PROBABLE CAUSE

Página 51

VDSC “LOCKED” DOOR In the unlikely event the door lock motor should fail in the “locked” position you will need: 1. To fashion a hook on the e

Página 54

PROXIMITY TO SIDE CABINET INSTALLATION 1. Range / Range tops may be installed directly adjacent to existing 36" high base cabinets. IMPORTANT-t

Página 55

PROXIMITY TO SIDE CABINET INSTALLATION (24” W. MODELS) 1. This range may be installed directly adjacent to existing 36” high base cabinets. IMPORTAN

Página 56

STABILITY DEVICE INSTALLATION INSTRUCTIONS 1. The anti-tip bracket is to be attached to the rear wall as shown. The dimension for the bracket loc

Página 57

RANGE LEVELING Careful leveling of the range is critical not only to performance, but also to allow the alignment of oven doors and drip tray. Close

Comentários a estes Manuais