SERVICE NOTEBOOK VCWB300 PROFESSONAL MODEL BUILT-IN FULL HEIGHT WINE COOLER
DISPLAY PANEL OPERATION Keyboard Entry Tone Indicates a pad was pressed, command read and accept. Zone Pad 1. Toggle between zones for set point
Display Pad 1. Activates control panel. Pressing button for 2 seconds toggles the display on/off. Entry tone will sound at after 2 seconds of pad
LEVELING ADJUSTMENTS DOOR STOP ADJUSTMENT 1. Using a 3/16” allen wrench, remove door stop pin located in bottom hinge. 2. The pin is factory
DIAGNOSTIC CHECK POINTS (Rfer to Wiring Schematic on Page 19) Number DescriptionA E1 Display Board Send 1 +5Vdc 2 data signals 3 ground E2 Touch
DIAGNOSTIC CHECK POINTS (con’t) E4 Thermister inputs (measured with thermisters disconnected). 1 to 8 3 to 4.5 VDC – TE2 (Evaporator Thermister #2
General Information: Approved Board Certification CSA – UL Suction 0.256” + 0.005” / - 0.003” Discharge 0.194” + 0.003” / - 0.003” Process 0.256
THERMISTER RESISTANCE READING Using a Cup of Water (full of ice) at 32°F , place the Thermister in the water and you should read approximately 7353 Ω
Solenoid Valve / Evaporator Fan FEATURES: Direct acting solenoid valve, designed to shut off refrigerating media. MOUNTING: Vertical with coil upw
VCWB300 WIRING SCHEMATIC 19
VCWB300 WIRING DIAGRAM 20
Table of Contents Technical Information--------------------------------------------------------------------- 4 Sealed System-------------------------
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE CORRECTION A. Warm temperature 1. Control set too warm
TROUBLESHOOTING GUIDE (con’t) PROBLEM POSSIBLE CAUSE CORRECTION A. Warm temperature b2 Check fo
TROUBLESHOOTING GUIDE (con’t) PROBLEM POSSIBLE CAUSE CORRECTION 5. Door Ajar a. (See page 21) 6. E
TROUBLESHOOTING GUIDE (con’t) PROBLEM POSSIBLE CAUSE CORRECTION 2. Refrigerant Valve a. Initiate man
TROUBLESHOOTING GUIDE (con’t) PROBLEM POSSIBLE CAUSE CORRECTION 4. No Power from 4. Check E15 to g
VCWB300 DDWB300 DESIGNER – DFWB300 FULL OVERLAY BUILT-IN FULL HEIGHT WINE COOLER VIKING TECHNICAL INFORMATION * DUE TO POSSIBLITY OF PERSONAL INJU
SEALED SYSTEM The sealed system consists of the following components (listed in order of refrigerant flow): 1 condenser coil 1 dryer assembly 3 sol
CONTROL PANEL ASSEMBLY The wine cooler is equipped with a control panel conveniently located in the top front of the top compartment of the wine coo
and appropriate zone valve based upon the temperature at the evaporator thermistor and will turn off the zone valve based upon the temperature at the
Showroom mode: This mode, selected by closing the showroom switch is intended to simulate normal operation in all ways except the cooling and temperat
GLASS MULLION SHELF Each compartment is separated be a fixed glass shelf (“Mullion” – two per wine cooler). These glass shelves are uniquely designe
DISPLAY PANEL KEYBOARD ELECTRONIC FUNCTION DESCRIPTION Power Disconnect Switch: The power on/off switch is used to turn the power off to the wine co
Comentários a estes Manuais